Gabion facing with a mesh tail that runs back into the fill — building the wall face and the soil reinforcement in one continuous unit.
A facia unit for a reinforced soil structure is a gabion-type facing box whose base panel continues as a long tail of double twisted mesh. The tail is laid between compacted layers of backfill, so the soil block itself becomes the retaining structure.
Vertical units build stepped or near-vertical walls; inclined units give a sloped, vegetated face at angles from 45° up to 87°. IS 16014:2024 specifies them in PVC coated wire only, because the tail is permanently buried.

Standard schedule, IS 16014:2024 Tables 4 (vertical) and 5 (inclined). PVC coated only.
| Parameter | 10×12 (D = 100 mm) | 8×10 (D = 80 mm) | 6×8 (D = 60 mm) |
|---|---|---|---|
| Mesh wire dia (ID/OD) | 2.70 / 3.70 mm | 2.70 / 3.70 mm | 2.20 / 3.20 mm |
| Edge / selvedge wire dia | 3.40 / 4.40 mm | 3.40 / 4.40 mm | 2.70 / 3.70 mm |
| Lacing wire dia | 2.20 / 3.20 mm | 2.20 / 3.20 mm | 2.20 / 3.20 mm |
| PVC coating thickness | Nominal 0.50 mm, minimum 0.40 mm | Nominal 0.50 mm, minimum 0.40 mm | Nominal 0.50 mm, minimum 0.40 mm |
| Vertical units (L × W × H) | 3–6 m × 2 or 3 m × 0.5, 0.8 or 1.0 m | ||
| Inclined units (L × W × H) | 3–6 m × 2 or 3 m × 0.63–0.83 m | Face angle 45°–87° | |
| Size tolerance | Length and width ±5%; height above 0.3 m ±5%, 0.3 m and below ±10% | Mesh opening D ±10% |